Gester Instruments | Professional Textile, Footwear and PPE Testing Equipments Manufacturers Since 1997
How to Test Firefighter Turnout Gear Thermal Protection?
As the core protective equipment for firefighters working in extreme environments such as high temperatures and flames, the thermal protective performance of firefighter turnout gear directly determines firefighters’ life safety. At fire scenes, firefighters are exposed to the dual threats of radiant heat and convective heat. High-quality protective clothing can effectively delay heat penetration, gaining valuable time for escape and rescue operations.
The GT-RC02 TPP Thermal Protection Tester, as a testing device specifically designed for this performance index, has become a mainstream instrument in the field of firefighting protective equipment testing thanks to its precise temperature control capability and test conditions that comply with international standards. It provides reliable technical support for the research and development, production inspection, and market supervision of protective clothing.
The primary task of firefighter turnout gear is to slow down the transfer of heat to human skin in high-temperature fire scenes, thereby reducing or preventing the occurrence of second-degree burns and above. However, thermal injury does not occur instantaneously; instead, it is closely related to the following factors:
Heat flux intensity (Heat Flux)
Exposure time (Exposure Time)
The thermal insulation capability of clothing materials and multi-layer structures
In real fire scenarios, firefighters are often exposed to complex thermal environments where radiant heat and convective heat coexist. Relying solely on material heat resistance indicators cannot truly reflect the protective capability of a complete set of turnout gear under actual wearing conditions.
The TPP Thermal Radiant Performance Tester is mainly used to test the thermal insulation properties of horizontally placed flame retardant protective clothing fabrics exposed to radiant and convective heat sources.
Under exposure to a specified heat flux, the time to second-degree burns is derived from the intersection point of the response curve (temperature rise curve of the calorimetric sensor) and the human tissue tolerance curve (Stoll curve). The higher the product of the heat flux level and the time to second-degree burns, the stronger the thermal protective performance of the fabric.
The higher the TPP value, the longer the effective protection time provided by the turnout gear in high-heat environments, and the stronger its thermal protective performance.
To ensure global applicability and authority of test results, TPP testing must strictly comply with international and industry standards. The standards widely adopted at present include:
ISO 17492:2019
ASTM F2700
ASTM F2703
NFPA 1971
NFPA 2112
Among them, NFPA 1971 specifies clear requirements for structural firefighting protective clothing:
The minimum TPP value of turnout gear must not be lower than 35
This value means that, under specified test conditions, the turnout gear can provide approximately 17.5 seconds of second-degree burn protection for firefighters, gaining a critical window for emergency evacuation or adjustment of operational strategies.
In practical testing, the stability of the equipment, the precision of heat source control, and the accuracy of data acquisition directly affect the reliability of TPP results. The TPP Thermal Protection Tester GT-RC02 is a professional device designed to meet international standards and high-end testing requirements.
This TPP Thermal Radiant Performance Tester is mainly used to test the thermal insulation performance of horizontally placed flame-retardant protective clothing fabrics under the combined effects of radiant and convective heat. It is widely applicable to firefighting, protective clothing, industrial flame-retardant materials, and scientific research fields.
A: TPP stands for Thermal Protective Performance. It is a key metric measuring a firefighter’s protective clothing’s ability to resist heat flux and prevent skin burns from thermal exposure.
A: The minimum TPP value specified in NFPA 1971 is 35 cal/cm².
A: A TPP tester is applicable for testing firefighter protective clothing fabrics, composite laminates, and complete garment assemblies.
A: The primary standards for TPP testing of firefighter clothing are NFPA 1971 and ISO 17492.
A: The core differences lie in three aspects: first, heat flux application mode (ISO 17492 uses controlled radiant and convective heat, while NFPA 1971 specifies a combined heat exposure protocol); second, evaluation endpoint (ISO 17492 focuses on time to second-degree burn, while NFPA 1971 defines a minimum TPP threshold for qualification); third, sample requirements (NFPA 1971 requires full garment components in some cases, while ISO 17492 allows fabric or laminate samples).