loading

Gester Instruments | Professional Textile Testing Equipment Manufacturers Since 1997


Test Standard
Test Standard

How to use gas masks

Gas masks refer to a type of protective equipment used for breathing after removing some toxic and harmful substances in the air by filtering. Masks are divided into full masks and half masks, and filter elements are divided into anti-virus, dust-proof and dust-toxin composite protection. Any protection is limited, and gas masks are no exception: it is not suitable for any hypoxic environment, because it does not produce oxygen; its protection Performance often depends on the effectiveness of filtration and the fit of the mask. Although people have been researching and applying gas masks for a long time, it is still impossible to invent a filtering method that is suitable for all harmful substances at the same time, so filter materials have their own scope of application. The function of the mask is to isolate the harmful environment from the filtered clean air. This isolation is also limited. Not only will there be a certain amount of air leakage in the components of the mask, but also the isolation method that relies on the fit of the face and the mask is not guaranteed. Absolutely tight, when inhaling, the air pressure in the mask will be lower than the outside world, and any leakage will allow harmful substances to enter the mask, so it cannot be used in a very high concentration environment. According to the relevant regulations of the state, the production of gas masks is strictly inspected and certified to ensure that such safety products can meet the minimum requirements recognized by the state. The inspection usually includes the evaluation of the sealing performance of the mask, and the inspection of the filtering effect of the filter element, and the effective filtering time of certain chemical substances of the specified concentration is determined to ensure a certain capacity. In the past, due to the lack of scientific normative guidance, based on some test data of gas masks alone, it happened from time to time to arbitrarily decide to use gas masks in some extremely dangerous environments, such as emergency rescue. As the name suggests, emergency rescue is not only dangerous, but also time-critical, and it is the most difficult type of environment for operators——The type of chemical substances encountered may be unknown, the concentration of harmful substances may be unknown, whether the environment is hypoxic may be unknown (especially in some small and confined spaces), and may be accompanied by other harsh conditions, such as burning, landslides, etc.; It takes time to find out the dangerous situation and confirm the level of concentration; in order to race against time to deal with the failure or save people, it is conceivable that the work intensity is huge. Using a gas mask in this situation, any small leak or filter element failure can lead to serious safety incidents! The national standard GB/T 18664-2002 'Selection, Use and Maintenance of Respiratory Protective Equipment', which came into effect in October 2002, has clearly identified the above rescue operations as the most dangerous type of environment.——Immediately life-threatening and health-threatening environmental treatment strictly limits the types of respiratory protective equipment that are allowed to be used, namely positive pressure air respirator with full face mask (see Figure 3), and positive pressure full face with suitable escape breathing equipment. Hood long-pipe air-supplied system (see Figure 4). Both types of safety equipment have safety features that gas masks do not have. First, use air cylinders and air supply pipes to provide breathing air, which is suitable for the presence of any type of hazardous substances; second, the full-face mask is a small positive pressure environment. When the wearer inhales, the air pressure in the mask remains higher than Environmental pressure, even if there is a small leak in the mask, external harmful substances cannot enter the mask; thirdly, the protection time is very certain, the air respirator has a certain use time guarantee, and the long-tube air supply system can allow long-term operation. These three elements of safety are not available in gas masks. In order to prevent problems before they occur and to prevent possible emergencies, it is necessary to formulate an emergency response plan in advance, prepare emergency facilities, including respiratory protection equipment, and provide training in advance, which are all safety guarantees for emergency operations. Only by ensuring the safety of the rescuers can we have the opportunity to curb the development of the accident, save the victims' lives in a timely manner, and try to restore all kinds of losses. More about: Filtration Efficiency Tester

The point for GESTER International Co.,Limited is that managerial processes are as important as other inputs in production and can create significant competitive advantage.

So, get ready to dazzle the world with a wide range of tensile tester manufacturers textile testing equipment! Buy one today!! Visit GESTER International Co.,Limited at GESTER Instruments.

Though the cost of these sustainability initiatives as textile testing equipment can be high, harnessing the power of an ethical supply chain to appeal to conscientious consumers can be a smart move both ethically and financially.

GESTER International Co.,Limited has developed its range of products around its own market research, which discovers customers' precise needs.

The development of tensile tester manufacturers textile testing equipment products has massive potential for expansion.

GET IN TOUCH WITH Us
recommended articles
Installation Training for the Incline Impact Tester GT-N49
Our expert team provides comprehensive on-site installation and training for the Incline Impact Tester GT-N49. This critical packaging testing equipment simulates real-world impacts during handling, transport, and stacking to evaluate product damage resistance. Learn about its key features like flexible moving plates, height adjustment, pneumatic angle control, and remote operation safety. Our service ensures proper setup, operational mastery, maintenance guidance, and troubleshooting support fo
Bally Leather Flexing Tester GT-KC10A Assembly Guide
This comprehensive guide provides detailed instructions for the proper assembly, calibration, and operation of the Bally Leather Flexing Tester GT-KC10A. Essential for quality control labs, it ensures accurate testing of flex resistance in leather, coated fabrics, and textiles used in footwear uppers, helping to prevent material failure.
Fabrics Specification Parameters and Testing Standards : A Complete Guide
These specifications outline the physical, mechanical, and functional characteristics of fabrics, while testing standards ensure that fabrics meet these predefined criteria. This synergy is vital in influencing manufacturing efficiency and end-user satisfaction, ensuring that products meet performance expectations across diverse applications.
Analysis of Pilling Influencing Factors and Testing Methods
Pilling testing plays a vital role in textile quality control, helping manufacturers evaluate and improve the wear performance of fabrics. Through the use of advanced instruments like ICI Pilling Box Test Method (GT-C18) , Martindale Abrasion Test Method (GT-C13B) , and Random Tumble Pilling Test Method (GT-C19A) , laboratories can conduct precise and standardized assessments, ensuring that final textile products deliver superior appearance, comfort, and longevity.
Understanding 3 Positions DIN Abrasion Tester : A Comprehensive Guide
This comprehensive guide explains the 3-Position DIN Abrasion Tester, a rotary drum instrument simulating real-world wear to quantify material abrasion resistance. Learn its working principle (mass/volume loss measurement under controlled friction), key features (touch-screen control, automated dust cleaning), and applications across rubber, tires, footwear, and conveyor belts. Discover compliant standards (DIN 53516, ISO 4649, ASTM D5963), step-by-step operation procedures, and essential mainte
Four Color Fastness Test Method for Laboratory Drying Oven
GESTER’s laboratory drying oven is designed for textile color fastness testing, including perspiration, seawater, water, and saliva resistance. Compliant with ISO, AATCC, GB, and JIS standards, it ensures precise heating and drying for accurate test results. Learn the step-by-step four color fastness test method and its applications.
What is The Test for Bond Strength?
The GT-N25 Bond Strength Tester evaluates interlayer bonding in paper, cardboard & composites (e.g., aluminum foil films). Ensures durability & quality compliance with GB/T, ASTM & TAPPI standards.
How to Conduct Whole Shoes Flexing Tester: Step-by-Step Process
This article explores the Whole Shoes Flexing Tester, focusing on its operation, applications, and features. It offers a detailed, step-by-step guide to help you conduct shoe flexing tests efficiently while improving the durability and performance of footwear products.
Understanding the Operation of Crush Tester
Crush Testers, such as the GT-N09, are essential tools in the packaging industry for evaluating the compressive strength of materials like cardboard and corrugated boards. This guide provides a detailed overview of testing methods like Edge Crush Test (ECT), Ring Crush Test (RCT), Flat Crush Test (FCT), Concora Medium Test (CMT), and Pin Adhesion Test (PAT). It also includes a step-by-step operation procedure for the GT-N09 Crush Tester and key precautions to ensure accurate and reliable test re
An Introduction to Footwear Electric Shock Resistant Tester GT-KB42
The GT-KB42 Footwear Electric Shock Resistant Tester by GESTER assesses the dielectric strength of safety shoes, boots, and insulating footwear to prevent workplace electrical hazards. Complying with ANSI, CSA, GB, and ASTM standards, it features precision voltage control, real-time leakage monitoring, and multi-standard compatibility—ideal for power utilities, construction, and industrial safety applications.
no data
QUANZHOU GESTER INTERNATIONAL CO.,LTD gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat

Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86 018059983973
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect