Application
The TPP thermal protection tester is mainly used to measure the thermal insulation performance of flame-retardant protective clothing fabrics exposed to radiant heat sources and convection heat sources to detect the thermal protection performance of protective clothing, safety shoes, gloves, and helmet outer surfaces.
Feature
3.Cooling system, can cooling the heat flow meter quickly, improve testing speed.
Key Specification
Model | GT-RC02 |
Specimen Size | 150×150mm |
Specimen Radiated Size | 100×100mm |
Radiant Thermal-Flux Source | 9pcs of 500w quartz burner; Interval: 13.0±0.5mm (Optional: 14.3±0.5mm for GB 8965.1 Standard) |
Convective Thermal-Flux Source | 2 burners at 20°to 30°angle from the vertical, Gas supply: Methane (Purity≥99%) or Propane (Purity≥95%) (Optional: 45°for GB 8965.1 Standard) |
Heat Flow Meter | K-Type Thermocouple wire (diameter ≤0.25mm), Resolution: 0.1℃, Accuracy: 0.7℃ |
Data Collection System | Collect frequency: 10Hz |
Radiant Thermal-Flux | (13 4)kW/m2[(0.3±0.1)cal/cm2×s] |
Whole Thermal-Flux | (84 2)kW/m2 [(2.00±0.05)cal/cm2×s] |
Power Supply | 220V 50Hz 5Kw |
Dimension | 930×740×890mm |
Weight | ≈100kg |
Standards | GB /38302-2019, GB 8965.1, NFPA 1971, ASTM F 2700-08, ASTM F 2703-08, ASTM D4018, ISO 17492 |
Contact Us Now
If you have any questions, please feel free to contact us
Copyright © 2019 GESTER International Co.,Limited | All Rights Reserved
Hello, please leave your name and email here before chat online so that we won't miss your message and contact you smoothly.