Temperature humidity chambers (also known as climatic or climate test chambers) simulate the effects that a range of temperature and humidity conditions have on a product or material, for example telecommunications equipment or photovoltaic solar panels that are exposed to outdoor temperature and humidity testing conditions. They have applications in industries as disparate as food science, semiconductors, and military quality assurance. A good temperature humidity chamber is essential for evaluating potential success or failure of a product in the field. A climate test chamber can also be used when constant climate conditions (temperature and/or humidity) are needed for product testing.
The main function of environmental testing chambers, is to test the behavior of the products we use every day, in extreme climatic conditions. Temperature And Humidity Test Chamber For conditioning of samples prior to testing. It also can be used for a variety of materials of high - low temperature alternating test. The test temperature, humidity and time can be programmed.
Temperature humidity test Feature
1. Touch screen, South Korean import,900 temperature controller
2. Temperature and Humidity Chamber Control mode: Touchpad
Display: LCD display, Korean TEMi880, programmable.
3. System capacity:120 groups program X100 sections, required segmentation sections of each group can be arbitrarily divided and each program can freely link another.
4. Cycle setting: each operation procedure can carry out 9999 times or heaps of times cycle and repeated performance, and to the degree, divide further 5 segmentation sections to do part cycle of the extra.
Temperature and humidity testing Test Methods
1. First of all, please check the environmental test equipment lines and water route for safety.
2. Before the test, please add pure water to the water tank and bring it to thewater level of about 80.
3. Please note that the water in the tank needs to be drained every half a month to a month to ensure the cleanliness.
4. lnstall one side of the absorbent cloth strip in the box from the top to the third pipe,and put the other side into the sink for suction.
5. Turn on the power. Put the sample into the box.
6. Set the required TEMP and HUMl, and select the running time of the test for testing.
7. When the set time machine is reached, it will stop automatically, or when the test results have reached therequirements, the test can be stopped manually. (Tips:Video just for reference.)
8. After the test, you can check the real graph and test report.
Edit a new program section and set the TEMP,HUMI and TIME required for each test section.
9. The program tests will be grouped according to the set test section, and the next set of tests willnot be carried out until the first set of tests freach the set time}, and so on, until all test groupsare completed, it will stop automatically.
10. Please note that when the test results have reached the requirements, you can manually stop the test.
11. After the test, you can check the real graph and test report.
12. View test data. (You can view the linear results of the test through the operation interface,or you can connect to the computer or insert USB to copy the data or view).